The Siemens SOMATOM Definition Flash redefines high-end diagnostic performance by pairing extreme speed with minimal radiation exposure. Engineered as Siemens’ flagship second-generation dual-source CT scanner, it addresses high-volume, high-acuity clinical environments like emergency departments, pediatric units, and advanced cardiovascular suites.
By operating two complete imaging chains simultaneously on an ultra-fast 0.28-second rotating gantry, the Definition Flash captures whole organs in fractions of a second. Patients with severe arrhythmias, elevated heart rates, or those unable to hold their breath no longer pose a challenge. Furthermore, its Selective Photon Shield filters out low-energy scatter, making spectral Dual Energy characterization routine at doses comparable to standard single-energy exams.
Key Features & Advanced Technologies
-
Flash Spiral Scan Mode: Operates at table feed speeds up to 458 mm/s (pitch up to 3.4). Acquires a complete thoracic scan in 0.6 seconds, eliminating respiratory motion artifacts without requiring patient breath-holds.
-
75 ms Native Temporal Resolution: Isolates rapid movement in coronary arteries without requiring beta-blocker pre-medication.
-
Selective Photon Shield (Dual Energy): Integrates tin filter technology into the high-kV tube assembly. Eliminates non-diagnostic low-energy photons to deliver dose-neutral Dual Energy material decomposition (e.g., virtual non-contrast, iodine mapping, bone removal).
-
Twin STRATON™ MX P Tubes: Direct-oil liquid cooling supplies an effective thermal dissipation rate of 7.3 MHU/min per tube. Offers 200 kW generator reserves (2 x 100 kW) for unlimited back-to-back scanning without thermal downtime.
-
Stellar Detector Array: Directly converts signals at the photodiode layer to eliminate electronic background noise, preserving sub-millimeter diagnostic contrast in low-kV and obese patient studies.
-
Comprehensive Dose Reduction Suite: Integrates SAFIRE™ model-based iterative reconstruction, CARE kV (automated voltage tuning), and Adaptive Dose Shield to lower overall dose profiles by up to 60%–80%.
Technical Specifications
| Parameter | Specification |
| Gantry Architecture | Dual Source (2 x STRATON™ Tubes / 2 x Stellar Detector Arrays) |
| Slice Capabilities | 2 x 128 (256-slice acquisition, reconstructive up to 384 slices) |
| Gantry Bore Aperture | 78 cm Clearance |
| Rotation Speed | 0.28 seconds full 360° gantry rotation |
| Temporal Resolution | 75 ms native in-plane |
| Max Scan Table Speed | Up to 458 mm/s (Flash Spiral pitch up to 3.4) |
| Generator Power | 200 kW Total Output (2 x 100 kW) |
| Dynamic Coverage | Up to 140 mm Z-axis coverage (Adaptive 4D Spiral) |
| Patient Table Load | Supports up to 227 kg (500 lbs) unrestricted |